HEM:FHS: assumptions and limits

HEM:FHS: assumptions and limits

Last updated: 26/11/2026

Where Vulcan makes an assumption to run HEM:FHS, and the limits of HEM:FHS that Vulcan cannot remove. Lines are for 1.0.0a9, the default, unless they say otherwise.

The version

  • 1.0.0a9 is not final. A later version is expected, and results may change.
  • 1.0.0a7 (older version). It counts appliance and cooking energy in the dwelling and target emission and primary energy rates, as its engine does, so its rates are higher. Use 1.0.0a9 for regulated-only rates.

Values Vulcan fills or corrects

  • Terrain class. Suburban when you give none.
  • Zones. HEM:FHS takes one zone, so Vulcan merges the drawn zones.
  • Input faults in 1.0.0a9. Vulcan corrects three, so that elements next to an unheated space, warm air heating and damper-only storage heaters run. The calculation is not changed. Vulcan corrects these until a later version fixes them.
  • Thermal mass class. The lightest class is 240 kJ/m²K, so a lighter element gets more thermal mass than it has and heats up and cools down more slowly.
  • Openable windows. Give each window its free area height. Vulcan works out its Mid height and Open area from the window's size and sill height, and keeps a value you type. A window with more than one part needs all three values for each part. A window that does not open takes Fixed under Part that opens and needs none of them.

How Vulcan enters the drawing

  • Heated basement. Sent as one ground floor element that includes the walls below ground.
  • Storey height. The height you type in the floor picker, else the height of the walls under the floor above, else the storey's tallest wall.
  • Zone floor area and volume. Vulcan works them out from the drawing. Each part of a storey counts at the mean height of its own walls, and the floor of a bay above the ground floor or of a conservatory open to the dwelling counts. A floor area or height you type is kept.
  • Conservatory. Draw a conservatory only if it is open to the home and heated. A separated conservatory is not part of the dwelling, so don't draw it. Vulcan keeps the wall between the conservatory and the home as an internal wall, so don't draw that wall again.
  • Distant shading. Angles are measured from the centre of the floor area, distance from the closest external wall.
  • Ground floor U-value. When a ground floor has a construction resistance and no U-value, Vulcan works out each part's U-value from the area and exposed perimeter of the storey's whole ground floor, and from that part's own construction. A U-value you type is kept. A file saved by an earlier version of Vulcan keeps its old exposed perimeter until you open and save it. That gives a slightly higher U-value, so open and save old files before a batch run.
  • Bay and conservatory floors. Vulcan enters a bay's ground floor as part of the ground floor it extends, with that floor's construction. A bay floor with a different construction is entered as a floor of its own, or stops the run if it is smaller than 5 m². A conservatory floor smaller than 5 m² also stops the run: make the conservatory larger.

Limits of HEM:FHS

  • Fan coils. HEM runs a fan coil only as the one emitter of its space heating. Vulcan says so on the fan coil before the run if its space heating has other emitters, and you give the fan coil a space heating of its own.
  • Heat network source. Vulcan has no input for a heat network supply yet, so a heat pump cannot take its heat from a heat network. Choose another source type.
  • Warm air heating. HEM runs it only from an air-to-air heat pump with no boiler (not a hybrid). Vulcan says so before the run if the linked heat source is anything else.
  • Shading beside the dwelling. HEM takes only a distance above 0 m, so an object level with or behind the closest wall, such as a terraced neighbour, cannot be entered. The editor says so.
  • Heating with temperature control only, on 1.0.0a9. HEM:FHS turns the heating on at the start of each heating period, with no early start. The rooms are then cold for the first half hour, and Results counts those hours as unmet heating. With time and temperature control, and on 1.0.0a7 with either control, HEM:FHS starts the heating up to 2 hours early.

See also

These notes match HEM:FHS 1.0.0a9. We update them with each Vulcan release. To report a wrong default, email support@usevulcan.app.